Clipsal 5502DAL Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Gateways / Controller Clipsal 5502DAL herunter. Clipsal 5502DAL User guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - C-Bus OPC installation

C-Bus OPC installation C-Bus programming guide

Seite 2 - Conventions in this guide

C-Bus OPC installation User Guide 6 © Schneider Electric 2011 1.4 Host computer system requirements The C-Bus OPC Server has the following host c

Seite 3 - Contents

Overview © Schneider Electric 2011 7 1.5 C-Bus OPC Server system configurations The C-Bus OPC Server can either be installed on its own computer

Seite 4

C-Bus OPC installation User Guide 8 © Schneider Electric 2011 1.7 Licensing Licensing of the C-Bus OPC Server is divided into three categories: d

Seite 5 - 1.0 Overview

Overview © Schneider Electric 2011 9 Licensing for the C-Bus OPC Server, when activated by a CITECT License, is based on the number of configured

Seite 6

C-Bus OPC installation User Guide 10 © Schneider Electric 2011 1.8 The OPC Data Access interface The OPC Data Access interface supports both Ligh

Seite 7

Overview © Schneider Electric 2011 11 The DALI application has been specified for use with the DALI mostly for the benefit of keeping DALI contro

Seite 8 - 1.3 Software layers

C-Bus OPC installation User Guide 12 © Schneider Electric 2011 1.8.1 How the OPC Data Access interface works A simple example of a C-Bus OPC Serv

Seite 9

Overview © Schneider Electric 2011 13 Messaging sequence The messaging sequences listed below are part of the process for translating C-Bus messa

Seite 10 - © Schneider Electric 2011

C-Bus OPC installation User Guide 14 © Schneider Electric 2011  Sequence 2: The C-Bus OPC Server receives the OPC message, translates this to C-

Seite 11 - 1.6 Modes of operation

Overview © Schneider Electric 2011 15 1.9 OPC Alarms and Events interface The OPC Alarms and Events interface provides information about the sta

Seite 12 - 1.7 Licensing

C-Bus OPC installation User Guide ii © Schneider Electric 2011 Conventions in this guide Before you start using this guide, it is important to u

Seite 13 - Multiple licenses

C-Bus OPC installation User Guide 16 © Schneider Electric 2011 The graphic below shows a C-Bus system containing output units such as the C-Bus Un

Seite 14

Overview © Schneider Electric 2011 17 1.9.1 Transmitting Error Reporting into OPC Alarms and Events error data The conversion of Error Reporting

Seite 15 - ESSAGES

C-Bus OPC installation User Guide 18 © Schneider Electric 2011 OPC mapping to either the Architectural dimmer or Professional dimmer units OPC err

Seite 16

Overview © Schneider Electric 2011 19 Control communication failure The Communication Error error condition indicates that an internal communicat

Seite 17 - © Schneider Electric 2011

C-Bus OPC installation User Guide 20 © Schneider Electric 2011 Event and alarm conditions The OPC Server receives Error Reporting messages from C-

Seite 18

Overview © Schneider Electric 2011 21 Figure 11: State diagram showing processing of alarm conditions Inactive, Acknowledged[Send "Condition

Seite 19

C-Bus OPC installation User Guide 22 © Schneider Electric 2011 Typical error condition names and their active and inactive states The table belo

Seite 20 - Figure 9: BMS Integration

Overview © Schneider Electric 2011 23 1.9.2 Quality of OPC Alarms and Events data and logged data The C-Bus OPC Server provides information on t

Seite 21

C-Bus OPC installation User Guide 24 © Schneider Electric 2011 The sequence illustrates the messaging sequences that occur to convert a error cond

Seite 22

Overview © Schneider Electric 2011 25 where FLOOR2 refers to the specific C-Bus network, DIMMER refers to the unit tag name, CHANNEL1 refers to t

Seite 23

© Schneider Electric 2011 iii Contents 1.0 Overview 1 1.1 Why have a C-Bus OPC Server?...

Seite 25 - Overview

© Schneider Electric 2011 27 The installation of the C-Bus OPC Server includes the software components described in the software layers in the O

Seite 26

C-Bus OPC installation User Guide 28 © Schneider Electric 2011 2.1.1 Installed software The installed components reside in the C:\Clipsal\CbusOPC

Seite 27

Installation © Schneider Electric 2011 29 2.3 Downloading and installing C-Bus Toolkit You can obtain the most recent copy of C-Bus Toolkit at t

Seite 29

31 © Schneider Electric 2011 C C-Bus OPC Server system configurations • 7 Conventions in this guide • ii D Downloading and installing C-Bus Toolk

Seite 31 - 2.0 Installation

© Schneider Electric 2011 1 The C-Bus OPC Server is a stand-alone software package made available by Clipsal to allow OPC communication between

Seite 32 - 2.1.1 Installed software

C-Bus OPC installation User Guide 2 © Schneider Electric 2011 How C-Bus messaging translates to OPC Server objects The C-Bus OPC Server utilises t

Seite 33

Overview © Schneider Electric 2011 3 1.1 Why have a C-Bus OPC Server? An obvious reason for installing and operating a C-Bus OPC Server is becau

Seite 34

C-Bus OPC installation User Guide 4 © Schneider Electric 2011 1.2 For more information OPC Foundation website The OPC Foundation http://www.opcfo

Seite 35 - 3.0 Index

Overview © Schneider Electric 2011 5 C-Bus OPC Commissioning Application The C-Bus OPC Commissioning Application is the programming interface for